Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
2.
PLoS Pathog ; 18(7): e1010631, 2022 07.
Article in English | MEDLINE | ID: covidwho-1933392

ABSTRACT

The S:A222V point mutation, within the G clade, was characteristic of the 20E (EU1) SARS-CoV-2 variant identified in Spain in early summer 2020. This mutation has since reappeared in the Delta subvariant AY.4.2, raising questions about its specific effect on viral infection. We report combined serological, functional, structural and computational studies characterizing the impact of this mutation. Our results reveal that S:A222V promotes an increased RBD opening and slightly increases ACE2 binding as compared to the parent S:D614G clade. Finally, S:A222V does not reduce sera neutralization capacity, suggesting it does not affect vaccine effectiveness.


Subject(s)
COVID-19 , SARS-CoV-2 , Angiotensin-Converting Enzyme 2/genetics , COVID-19/genetics , Genetic Background , Humans , Mutation , Peptidyl-Dipeptidase A/metabolism , Protein Binding , Receptors, Virus/metabolism , SARS-CoV-2/genetics , Spike Glycoprotein, Coronavirus/metabolism
3.
Sci Rep ; 12(1): 8273, 2022 05 18.
Article in English | MEDLINE | ID: covidwho-1931478

ABSTRACT

Combined kinetic analysis of plasma SARS-CoV-2 RNAemia, Nucleocapsid (N)-antigenemia and virus-specific antibodies may help ascertain the role of antibodies in preventing virus dissemination in COVID-19 patients. We performed this analysis in a cohort of 71 consecutive critically ill COVID-19 patients (49 male; median age, 65 years) using RT-PCR assay, lateral flow immunochromatography method and receptor binding domain (RBD) and N-based immunoassays. A total of 338 plasma specimens collected at a median of 12 days after symptoms onset were available for analyses. SARS-CoV-2 RNAemia and N-antigenemia were detected in 37 and 43 specimens from 26 (36.5%) and 30 (42.2%) patients, respectively. Free RNA was the main biological form of SARS-CoV-2 found in plasma. The detection rate for both viral components was associated with viral load at the upper respiratory tract. Median time to SARS-CoV-2-RBD antibody detection was 14 days (range, 4-38) from onset of symptoms. Decreasing antibody levels were observed in parallel to increasing levels of both RNAemia and N-antigenemia, yet overall a fairly modest inverse correlation (Rho = -0.35; P < 0.001) was seen between virus RNAemia and SARS-CoV-2-RBD antibody levels. The data cast doubts on a major involvement of antibodies in virus clearance from the bloodstream within the timeframe examined.


Subject(s)
COVID-19 , SARS-CoV-2 , Adult , Aged , Antibodies, Viral , Critical Illness , Humans , Kinetics , Male , RNA, Viral/analysis
4.
Biosens Bioelectron ; 213: 114454, 2022 Oct 01.
Article in English | MEDLINE | ID: covidwho-1881712

ABSTRACT

The impact of the COVID-19 pandemic has reinforced the need for rapid, cost-effective, and reliable point-of-care testing (POCT) devices for massive population screening. The co-circulation of SARS-CoV-2 with several seasonal respiratory viruses highlights the need for multiplexed biosensing approaches. Herein, we present a fast and robust all-in-one POCT device for parallel viral antigen and serological analysis. The biosensing approach consists of a functionalized polycarbonate disc-shaped surface with microfluidic structures, where specific bioreagents are immobilized in microarray format, and a portable optoelectronic analyzer. The biosensor quantifies the concentration of viral antigens and specific immunoglobulins G and M for SARS-CoV-2, influenza A/B, adenovirus, and respiratory syncytial virus, using 30 µL of a sample. The semi-automated analysis of 6 samples is performed in 30 min. Validation studies performed with 135 serum samples and 147 nasopharyngeal specimens reveal high diagnostic sensitivity (98-100%) and specificity (84-98%), achieving an excellent agreement (κ = 0.937) with commercial immunoassays, which complies with the World Health Organization criteria for POC COVID-19 diagnostic tests. The versatility of the POCT device paves the way for the detection of other pathogens and analytes in the incoming post-pandemic world, integrating specific bioreagents against different variants of concerns and interests.


Subject(s)
Biosensing Techniques , COVID-19 , Influenza, Human , Respiratory Tract Infections , Antigens, Viral/analysis , COVID-19/diagnosis , Humans , Influenza, Human/diagnosis , Pandemics , Point-of-Care Systems , Point-of-Care Testing , Respiratory Tract Infections/diagnosis , SARS-CoV-2 , Sensitivity and Specificity
5.
J Med Virol ; 94(1): 222-228, 2022 01.
Article in English | MEDLINE | ID: covidwho-1372751

ABSTRACT

The current study aimed at characterizing the dynamics of SARS-CoV-2 nucleocapsid (N) antigenemia in a cohort of critically ill adult COVID-19 patients and assessing its potential association with plasma levels of biomarkers of clinical severity and mortality. Seventy-three consecutive critically ill COVID-19 patients (median age, 65 years) were recruited. Serial plasma (n = 340) specimens were collected. A lateral flow immunochromatography assay and reverse-transcription polymerase chain reaction (RT-PCR) were used for SARS-CoV-2 N protein detection and RNA quantitation and in plasma, respectively. Serum levels of inflammatory and tissue-damage biomarkers in paired specimens were measured. SARS-CoV-RNA N-antigenemia and viral RNAemia were documented in 40.1% and 35.6% of patients, respectively at a median of 9 days since symptoms onset. The level of agreement between the qualitative results returned by the N-antigenemia assay and plasma RT-PCR was moderate (k = 0.57; p < 0.0001). A trend towards higher SARS-CoV-2 RNA loads was seen in plasma specimens testing positive for N-antigenemia assay than in those yielding negative results (p = 0.083). SARS-CoV-2 RNA load in tracheal aspirates was significantly higher (p < 0.001) in the presence of concomitant N-antigenemia than in its absence. Significantly higher serum levels of ferritin, lactose dehydrogenase, C-reactive protein, and D-dimer were quantified in paired plasma SARS-CoV-2 N-positive specimens than in those testing negative. Occurrence of SARS-CoV-2 N-antigenemia was not associated with increased mortality in univariate logistic regression analysis (odds ratio, 1.29; 95% confidence interval, 0.49-3.34; p = 0.59). In conclusion, SARS-CoV-2 N-antigenemia detection is relatively common in ICU patients and appears to associate with increased serum levels of inflammation and tissue-damage markers. Whether this virological parameter may behave as a biomarker of poor clinical outcome awaits further investigations.


Subject(s)
COVID-19/virology , Coronavirus Nucleocapsid Proteins/blood , Critical Illness , SARS-CoV-2 , Adult , Aged , Aged, 80 and over , Antigens, Viral/blood , Biomarkers/analysis , Biomarkers/blood , COVID-19/mortality , Coronavirus Nucleocapsid Proteins/immunology , Female , Humans , Inflammation , Male , Middle Aged , Phosphoproteins/blood , Phosphoproteins/immunology , Prospective Studies , RNA, Viral/analysis , RNA, Viral/blood , SARS-CoV-2/genetics , SARS-CoV-2/immunology , SARS-CoV-2/isolation & purification , Trachea/virology , Young Adult
6.
J Clin Virol ; 142: 104943, 2021 09.
Article in English | MEDLINE | ID: covidwho-1347689

ABSTRACT

BACKGROUND: There is an imperative need to determine the durability of adaptive immunity to SARS-CoV-2. We enumerated SARS-CoV-2-reactive CD4+ and CD8+ T cells targeting S1 and M proteins and measured RBD-specific serum IgG over a period of 2-6 months after symptoms onset in a cohort of subjects who had recovered from severe clinical forms of COVID-19. PATIENTS AND METHODS: We recruited 58 patients (38 males and 20 females; median age, 62.5 years), who had been hospitalized with bilateral pneumonia, 60% with one or more comorbidities. IgG antibodies binding to SARS-CoV-2 RBD were measured by ELISA. SARS-CoV-2-reactive CD69+-expressing-IFNγ-producing-CD4+ and CD8+ T cells were enumerated in heparinized whole blood by flow cytometry for ICS. RESULTS: Detectable SARS-CoV-2-S1/M-reactive CD69+-IFN-γ CD4+ and CD8+ T cells were displayed in 17 (29.3%) and 6 (10.3%) subjects respectively, at a median of 84 days after onset of symptoms (range, 58-191 days). Concurrent comorbidities increased the risk (OR, 3.15; 95% CI, 1.03-9.61; P = 0.04) of undetectable T-cell responses in models adjusted for age, sex and hospitalization ward. Twenty-one out of the 35 patients (60%) had detectable RBD-specific serum IgGs at a median of 118 days (range, 60-145 days) after symptoms onset. SARS-CoV-2 RBD-specific IgG serum levels were found to drop significantly over time. CONCLUSION: A relatively limited number of subjects who developed severe forms of COVID-19 had detectable SARS-CoV-2-S1/M IFNγ CD4+ and CD8+ T cells at midterm after clinical diagnosis. Our data also indicated that serum levels of RBD-specific IgGs decline over time, becoming undetectable in some patients.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , CD8-Positive T-Lymphocytes , Female , Humans , Immunity , Male , Middle Aged
8.
J Med Virol ; 93(4): 2301-2306, 2021 04.
Article in English | MEDLINE | ID: covidwho-1217381

ABSTRACT

Assessment of commercial severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) immunoassays for their capacity to provide reliable information on sera neutralizing activity is an emerging need. We evaluated the performance of two commercially available lateral flow immunochromatographic assays (LFIC; Wondfo SARS-CoV-2 Antibody test and the INNOVITA 2019-nCoV Ab test) in comparison with a SARS-CoV-2 neutralization pseudotyped assay for coronavirus disease 2019 (COVID-19) diagnosis in hospitalized patients and investigate whether the intensity of the test band in LFIC associates with neutralizing antibody (NtAb) titers. Ninety sera were included from 51 patients with moderate to severe COVID-19. A green fluorescent protein (GFP) reporter-based pseudotyped neutralization assay (vesicular stomatitis virus coated with SARS-CoV-2 spike protein) was used. Test line intensity was scored using a 4-level scale (0 to 3+). The overall sensitivity of LFIC assays was 91.1% for the Wondfo SARS-CoV-2 Antibody test, 72.2% for the INNOVITA 2019-nCoV IgG, 85.6% for the INNOVITA 2019-nCoV IgM, and 92.2% for the NtAb assay. Sensitivity increased for all assays in sera collected beyond day 14 after symptoms onset (93.9%, 79.6%, 93.9%, and 93.9%, respectively). Reactivities equal to or more intense than the positive control line (≥2+) in the Wondfo assay had a negative predictive value of 100% and a positive predictive value of 96.4% for high NtAb50 titers (≥1/160). Our findings support the use of LFIC assays evaluated herein, particularly the Wondfo test, for COVID-19 diagnosis. We also find evidence that these rapid immunoassays can be used to predict high SARS-CoV-2-S NtAb50 titers.


Subject(s)
Antibodies, Neutralizing/blood , COVID-19 Testing/methods , COVID-19/immunology , Immunoassay/methods , SARS-CoV-2/immunology , Antibodies, Neutralizing/immunology , Antibodies, Viral/blood , Antibodies, Viral/immunology , COVID-19/blood , COVID-19/diagnosis , COVID-19/virology , Green Fluorescent Proteins , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Spike Glycoprotein, Coronavirus/immunology
9.
Eur J Clin Microbiol Infect Dis ; 40(3): 485-494, 2021 Mar.
Article in English | MEDLINE | ID: covidwho-1009150

ABSTRACT

Whether antibody levels measured by commercially available enzyme or chemiluminescent immunoassays targeting the SARS-CoV-2 spike (S) protein can act as a proxy for serum neutralizing activity remains to be established for many of these assays. We evaluated the degree of correlation between neutralizing antibodies (NtAb) binding the SARS-CoV-2 spike (S) protein and SARS-CoV-2-S-IgG levels measured by four commercial immunoassays in sera drawn from hospitalized COVID-19 patients. Ninety sera from 51 hospitalized COVID-19 patients were tested by a pseudotyped virus neutralization assay, the LIAISON SARS-CoV-2 S1/S2 IgG, the Euroimmun SARS-CoV-2 IgG ELISA, the MAGLUMI 2019-nCoV IgG, and the COVID-19 ELISA IgG assays. Overall, the results obtained with the COVID-19 ELISA IgG test showed the highest agreement with the NtAb assay (κ, 0.85; 95% CI, 0.63-1). The most sensitive tests were the pseudotyped virus NtAb assay and the COVID-19 ELISA IgG assay (92.2% for both). Overall, the degree correlation between antibody titers resulting in 50% virus neutralization (NtAb50) in the pseudotyped virus assay and SARS-CoV-2 IgG levels was strong for the Euroimmun SARS-CoV-2 IgG ELISA (rho = 0.73) and moderate for the remaining assays (rho = 0.48 to 0.59). The kinetic profile of serum NtAb50 titers could not be reliably predicted by any of the SARS-CoV-2 IgG immunoassays. The suitability of SARS-CoV-2-S-IgG commercial immunoassays for inferring neutralizing activity of sera from hospitalized COVID-19 patients varies widely across tests and is influenced by the time of sera collection after the onset of symptoms.


Subject(s)
Antibodies, Neutralizing/blood , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Immunoassay/methods , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Adult , Aged , Antibodies, Viral/blood , COVID-19/blood , Female , Hospitalization , Humans , Immunoglobulin G/blood , Kinetics , Male , Middle Aged , Neutralization Tests , Sensitivity and Specificity
10.
J Clin Virol ; 131: 104611, 2020 10.
Article in English | MEDLINE | ID: covidwho-738089

ABSTRACT

BACKGROUND: The involvement of SARS-CoV-2 antibodies in mediating immunopathogenetic events in COVID-19 patients has been suggested. By using several experimental approaches, we investigated the potential association between SARS-CoV-2 IgGs recognizing the spike (S) protein receptor-binding domain (RBD), neutralizing antibodies (NtAb) targeting S, and COVID-19 severity. PATIENTS AND METHODS: This unicenter, retrospective, observational study included 51 hospitalized patients (24 at the intensive care unit; ICU). A total of 93 sera from these patients collected at different time points from the onset of symptoms were analyzed. SARS-CoV-2 RBD IgGs were quantitated by ELISA and NtAb50 titers were measured in a GFP reporterbased pseudotyped virus platform. Demographic and clinical data, complete blood counts, as well as serum levels of ferritin, Dimer-D, C reactive protein (CRP), lactose dehydrogenase (LDH), and interleukin-6 (IL-6) were retrieved from clinical charts. RESULTS: The overall correlation between levels of both antibody measurements was good (Rho = 0.82; P = 0 < 0.001). SARS-CoV-2 RBD IgG and NtAb50 levels in sera collected up to day 30 after the onset of symptoms were comparable between ICU and non-ICU patients (P=>0.1). Four ICU patients died; two of these achieved NtAb50 titers ≥1/160 while the other two exhibited a 1/80 titer. Very weak (Rho=>0.0-<0.2) or weak (Rho=>0.2-<0.4) correlations were observed between anti-RBD IgGs, NtAb50, and serum levels pro-inflammatory biomarkers. CONCLUSIONS: The data presented herein do not support an association between SARS-CoV-2 RBD IgG or NtAb50 levels and COVID-19 severity.


Subject(s)
Antibodies, Viral/blood , Coronavirus Infections/blood , Hospitalization/statistics & numerical data , Inflammation/blood , Pneumonia, Viral/blood , Adult , Aged , Antibodies, Neutralizing/blood , Betacoronavirus , Binding Sites, Antibody , Biomarkers/blood , COVID-19 , Coronavirus Infections/immunology , Female , Humans , Inflammation/virology , Male , Middle Aged , Pandemics , Pneumonia, Viral/immunology , Retrospective Studies , SARS-CoV-2 , Severity of Illness Index , Spike Glycoprotein, Coronavirus/immunology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL